The Effectiveness of Chlorine Tablets to Reducing Coliform in Wastewater Treatment Plant
DOI:
https://doi.org/10.31938/jsn.v12i1.340Abstract
Wastewater originating from experimental animal cages that are not treated properly can be a source of pollution because it contains organic, inorganic materials and even pathogenic microorganisms. Disinfection using chlorine is the last step in the wastewater treatment process to reduce microorganisms. This study aimed to determine the effectiveness of chlorine tablets in reducing the content of Coliform from experimental animal cage wastewater at the Wastewater Treatment Plant (WWTP) to meet the Total Coliform quality standard in the Regulation of the Minister of Environment and Forestry No. 68 of 2016 concerning domestic wastewater quality standards. The research was conducted using laboratory experiments pre and post-test. Wastewater samples were taken from 2 points, namely, the point inlet (before treatment) and outlet (after chlorination), the MPN test Coliform (SNI 2897 2008) were repeated twice, and the measured pH and temperature to analyze environmental factors. The results showed that 200 g of chlorine tablets could effectively reduce Coliform up to 98.55% and meet the quality standards used as a reference.
Keywords: Coliform, Chlorine, Wastewater, WWTP, Quality standard
Â
Efektivitas Tablet Klorin Dalam Menurunkan Kandungan Coliform Pada Instalasi Pengolahan Air Limbah
ABSTRAK
Air limbah yang berasumber dari kandang hewan coba yang tidak diolah dengan tepat dapat menjadi sumber pencemaran karena mengandung bahan organik, anorganik bahkan mikroorganisme pathogen. Desinfeksi meggunakan klorin merupakan tahapan terakhir pada proses pengolahan air limbah untuk mengurangi mikroorganisme. Tujuan dari penelitian ini adalah mengetahui efektivitas tablet klorin dalam menurunkan kandungan Coliform dari air limbah kandang hewan coba di Instalasi Pengolahan Air Limbah (IPAL) agar memenuhi baku mutu Total Coliform dalam Peraturan Menteri Lingkungan Hidup dan Kehutanan No. 68 Tahun 2016 tentang baku mutu air limbah domestik. Penelitian dilakukan dengan menggunakan eksperimen laoboratorium pre dan post test. Sampel air limbah diambil dari 2 titik yaitu titik inlet (sebelum pengolahan) dan outlet (sesudah klorinasi), uji MPN Coliform (SNI 2897 2008) Â dilakukan dua kali ulangan, serta mengukur pH dan suhu untuk menganalisis faktor lingkungan. Hasil penelitian menunjukkan tablet klorin sebanyak 200 g efektif dapat menurunkan Coliform hingga 98,55 % dan memenuhi baku mutu yang dijadikan acuan.
Kata Kunci: Coliform, Klorin, air limbah, IPAL dan baku mutu.
Downloads
References
Agung. (2009). Analisis Kadar Khlorida Pada Air Dan Air Limbah Dengan Metode Argentometri. Karya Tulis. Universitas Sumatera Utara. Medan
Aminah, S., & Wahyuni, S. (2018). Hubungan Konstruksi Sumur Dan Jarak Sumber Pencemaran Terhadap Total Coliform Air Sumur Gali Di Dusun 3A Desa Karang Anyar Kecamatan Jati Agung Kabupaten Lampung Selatan Relationship Construction Well And Distance Source Pollution Against Total Coliform W. Jurnal Analisis Kesehatan, 7(1), 1–6. ejurnal.poltekkes-tjk.ac.id/index.php/Janaliskes/article/view/921
Astika, A. U. W., Sudarno, S., & Zaman, B. (2017). Kajian Kinerja Bak Settler, Anaerobic Baffled Reactor (Abr), Dan Anaerobic Filter (Af) Pada Tiga Tipe Ipal Di Semarang. Jurnal Teknik Lingkungan, 6(1), 1–15.
Balai Besar Pengujian Mutu dan Sertifikasi Obat Hewan. (2012). Analisis Dampak Lingkungan. Panduan Mutu. Bogor.
Busyairi, M., Dewi, Y. P., & Widodo, D. I. (2016). Efektivitas Kaporit Pada Proses Klorinasi Terhadap Penurunan Bakteri Coliform Dari Limbah Cair Rumah Sakit X Samarinda (The Effectiveness of Calcium Hypochlorite to Chlorination Process in Decreasing the Amount of Coliform Bacteria in the Wastewater of X). Jurnal Manusia Dan Lingkungan, 23(2), 156. https://doi.org/10.22146/jml.18786
Hasan, A. (2006). Dampak penggunaan klorin. J. Tek. Lingk. P3TL-BPPT, 7(1), 90–96. http://ejurnal.bppt.go.id/ejurnal2011/index.php/JTL/article/view/456/472
Jiwintarum, Y., Agrijanti, & Septiana, B. L. (2017). Most Probable Number (Mpn) Coliform Dengan Variasi Volume Media Lactose Broth Single Strength (Lbss) Dan Lactose Broth Double Strength (Lbds). Jurnal Kesehatan Prima, 11(1), 1.
Kartikasari, A. M., Hamid, I. S., Purnama, M. T. E., Damayanti, R., Fikri, F., & Praja, R. N. (2019). Isolasi dan Identifikasi Bakteri Escherichia coli Kontaminan Pada Daging Ayam Broiler Di Rumah Potong Ayam Kabupaten Lamongan. Jurnal Medik Veteriner, 2(1), 66. https://doi.org/10.20473/jmv.vol2.iss1.2019.66-71
Kerubun, A. A. (2014). Wastewater Quality in Tulehu Regional Public Hospital Ali. Media Kesehatan Masyarakat Indonesia, 180–185.
Nugrayanti, M. S., Dermawan, D., & Dewi, T. U. (2018). Pengaruh pemberian dosis trichloroisocyanuric acid (tcca) pada bak desinfeksi terhadap penurunan kandungan escherichia coli di RSUD Dr. R. Koesma Tuban. Conference Proceeding on Waste Treatment Technology, 1(1), 129–134.
Peraturan Menteri. (2016). Peraturan Menteri Lingkungan Hidup dan Kehutanan No. 68 Tahun 2016 Tentang Baku Mutu Air Limbah Domestik.
Putri, A. M., & Kurnia, P. (2018). Identifikasi Keberadaan Bakteri Coliform Dan Total Mikroba Dalam Es Dung-Dung Di Sekitar Kampus Universitas Muhammadiyah Surakarta. Media Gizi Indonesia, 13(1), 41. https://doi.org/10.20473/mgi.v13i1.41-48
Sawyer, C.N., P.L. McCarty., G.F. Parkin. (2003). Chemistry for Enviromental Engineering and Science. McGrawHill. New York.
Sulistiyawati, I. (2019). Kuantitas Total Bakteri Coliform pada Instalasi Pengolahan Limbah Cair Medis Laboratorium Klinik. Jurnal Ilmiah Universitas Batanghari Jambi, 19(3), 675. https://doi.org/10.33087/jiubj.v19i3.718
Supriyadi., Sumantri, I., & Hartati., I. (2010). Pengaruh Dosis Klorin Pada Pertumbuhan Bakteri Coliform Total Dan Escherichia Coli Pada Sungai Kreo, Sungai Garang Dan Sungai Tugu Suharto. Banlit Fakultas Teknik-Universitas Wahid Hasyim Semarang, 12(1), 30–35.
Suri, P.M. 2019. Analisa Kadar Klorin Pada Air Kolam Renang Deli Di Kota Medan. Karya Tulis Ilmiah. Politeknik Kesehatan Kemenkes. Medan.
Susanthi, D., Purwanto, M. Y., & Suprihatin, S. (2018). Evaluasi Pengolahan Air Limbah Domestik dengan IPAL Komunal di Kota Bogor. Jurnal Teknologi Lingkungan, 19(2), 229. https://doi.org/10.29122/jtl.v19i2.2834
Widyaningsih, W., Supriharyono, S., & Widyorini, N. (2016). Analisis Total Bakteri Coliform Di Perairan Muara Kali Wiso Jepara. Management of Aquatic Resources Journal (MAQUARES), 5(3), 157–164. https://doi.org/10.14710/marj.v5i3.14403
Widyastuti, F. R., Purwanto, & Hadiyanto. (2013). Upaya pengelolaan lingkungan usaha peternakan sapi di Kawasan Usahatani Terpadu Bangka Botanical Garden Pangkalpinang. Prosiding Seminar Nasional Pengelolaan Sumber Daya Alam Dan Lingkungan Dalam Mewujudkan Pembangunan Berkelanjutan, 237, 81–85. http://www.psil.undip.ac.id
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2022 Sri Arofah Mulyati, Mia Azizah, Srikandi Srikandi, Maidaswar Maidaswar, Neneng Atikah
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
You are free to:
- Share — copy and redistribute the material in any medium or format for any purpose, even commercially.
- Adapt — remix, transform, and build upon the material for any purpose, even commercially.
- The licensor cannot revoke these freedoms as long as you follow the license terms.
Under the following terms:
- Attribution - You must give appropriate credit , provide a link to the license, and indicate if changes were made . You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
- ShareAlike - If you remix, transform, or build upon the material, you must distribute your contributions under the same license as the original.
- No additional restrictions - You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.